Sentinel CPPM-4 CO2 Controller
The CPPM-4 Co2 Controller controls your carbon dioxide levels with part-per-million accuracy. It uses a CO2 sensor that is extremely accurate and features a ten-year life expectancy. Our combination CO2 and light level sensor is housed in a separate remote sensor enclosure that can be located up to 100 ft from the controller. The CPPM-4 can also be connected to other controllers so that the CO2 is disabled (useful when operating exhaust fans). It can be operated in fuzzy-logic mode (for compressed CO2), or on-off (for CO2 generators).
Sentinel CHHC-4/Total Environmental Controller
The CHHC-4 Total Environmental Controller has the same button controls, layout and design as its predecessor, the CHHC-1, but we've made some drastic improvements! We've added plant friendly green LED displays to avoid plant cycle disruption. We've introduced weather resistant housing to avoid controller contamination. We have installed a removable remote probe assembly for easy product placement and probe replacement. We have added a dual beam CO2 sensor - the highest tech, most accurate sensor available to the hobby hydroponics industry. Most importantly, we have incorporated ROHS compliant construction to reduce the use of hazardous materials in the construction of Sentinel products. It is our mission to produce high quality, reliable products while remaining environmentally responsible. The CHHC-4 accomplishes that and so much more!
Titan Controls Kronus 2
The Kronus 2™ controls temperature, humidity and CO2 in your grow area at your preferred settings. The built in ten minute ‘CO2 Delay’ deactivates the CO2 equipment if settings are exceeded using a digitally based system. The software polls temperature and humidity settings for ten minutes after the CO2 is defeated to verify that the conditions are too high, then activates your equipment to lower the conditions below your settings. If your conditions drop below the set point during the 10 minute ‘CO2 Delay’, then the ventilation process is defeated and the ‘CO2 ON’ outlet is reactivated, saving your valuable CO2 and keeping it amongst the plants. The ‘CO2 ON’ feature is only activated during daylight periods to dose CO2 when your plants are able to uptake it, and is disabled during the nighttime hours or when the humidity or temperature exceeds the preferred settings.
Controls temperature, humidity and CO2 in your garden.
Activates 'CO2 ON’ outlet only during daylight hours.
Ten (10) minute ‘CO2 delay’ feature allows maximum CO2 coverage with minimum CO2 waste.
Easy to understand and use with highlighted ‘Grow Zones’.
25 foot modular remote temperature and humidity sensor.
15 Amps/120 Volts/60 Hz.
Improves your yield by creating the perfect environment for your plants.
3 year warranty.
Titan Controls Kronus 3
The Kronus 3™ controls temperature (day & night) and CO2 in your grow area at your preferred settings. The ‘CO2 ON’ feature is only activated during daylight periods to dose CO2 when your plants are able to uptake it, and is disabled during the nighttime hours or when the temperature exceeds your preferred settings. The built in ten (10) minute ‘CO2 delay’ feature deactivates CO2 equipment if the day temperature setting is exceeded. The ‘Night Only’ output allows use of a nightlight or circulation fan. The ‘Night Heat Output’ is used to plug a heater into to keep your plants from getting the night chills. The Kronus 3™ is the ultimate in temperature controls!
Controls day and night temperature and CO2 in your garden.
Activates 'CO2 ON’ outlet only during daylight hours.
Ten (10) minute ‘CO2 delay’ feature allows maximum CO2 coverage with minimum CO2 waste.
Features a ‘Night Only’ and ‘Night Heat’ outputs to assist the gardener with the maintenance of the garden after the lights have turned off.
Easy to understand and use with highlighted ‘Grow Zones’.
25 foot modular remote temperature sensor.
Improves your yield by creating the perfect environment for your plants.
15 Amps/120 Volts/60 Hz. 3 year warranty.
Titan Controls Kronus 4
The Kronus 4™ controls temperature, humidity and CO2 in your grow area at your preferred settings. The built in ten (10) minute ‘CO2 delay’ feature deactivates CO2 equipment if the temperature or humidity settings are exceeded. The ‘CO2 ON’ feature is only activated during daylight periods to dose CO2 when your plants are able to uptake it, and is disabled during the nighttime hours or when the humidity or temperature exceeds the preferred settings. The ‘Night Only’ output allows use of a nightlight or circulation fan. The Kronus 4™ gives the expert gardener the top shelf controller they’re looking for to maintain their garden!
Controls CO2, DAY/NIGHT temperature and humidity in your garden.
Activates 'CO2 ON’ outlet only during daylight hours.
Ten (10) minute ‘CO2 delay’ feature allows maximum CO2 coverage with minimum CO2 waste.
Features a ‘Night Only’ output to assist the gardener with the maintenance of the garden after the lights have turned off.
Easy to understand and use highlighted ‘Grow Zones’.
25 foot modular remote temperature and humidity sensor.
Improves your yield by creating the perfect environment for your plants.
perform CO2 enrichment during the day only (when light is sensed by the photocell). The enrichment starts when the CO2 concentration falls below the set point minus the differential. (i.e. Set point = 1200 ppm Differential = 150, CO2 enrichment starts below 1050 ppm and stops beyond 1350 ppm). The differential modifies itself until the controller senses no more overshooting or undershooting of user set point. Fixed differential values can also be set for more specific needs. As a safety feature, the high temperature shut off function will inhibit operation while temperature is over the user setting. To inhibit this feature, simply set the limit to its highest value. The controller can also be set to vent (extract) CO2. In this case, the high temp The iGS-061 Intelligent growing systems Co2 Controller will perform CO2 enrichment during the day only (when light is sensed by the photocell). The enrichment starts when the CO2 concentration falls below the set point minus the differential. (i.e. Set point = 1200 ppm Differential = 150, CO2 enrichment starts below 1050 ppm and stops beyond 1350 ppm). The differential modifies itself until the controller senses no more overshooting or undershooting of user set point. Fixed differential values can also be set for more specific needs. As a safety feature, the high temperature shut off function will inhibit operation while temperature is over the user setting. To inhibit this feature, simply set the limit to its highest value. The controller can also be set to vent (extract) CO2. In this case, the high temp shut off feature becomes a low temp shut off limit to prevent excessive cooling conditions. Features 3 year warranty.
Nova Day & Night Controller - Model iGS-220
The iGS-220 CO2 relative humidity and temperature controller is the simplest and most complete solution to integrated climate management and CO2 enrichment or venting. The resulting climate can increase yields and quality of harvest while insuring CO2 and energy savings. The electronic module displays the actual values of the CO2, relative humidity and temperature sensors. The controller includes an internal fan to speed up the air sampling process thus yielding better climate control. The control unit can be positioned up to 6 feet away from the output box (a cable up to 50 feet can be used). The control unit logs the last 24 hours minimum, maximum and average CO2 concentration, relative humidity and temperature values. Multiple operation modes are available and the differential of operation is adjustable.
CO2 Test Kit
Co2 Test Kit: 1 - 100cc syringe, 2 - rae systems test tubes and instructions.
Co2 Detector Tubes: 300 - 5000 ppmv, Sample Volume: 100 ml, Sample Time: 2 min., Color: White to Purple. Box contains 10 tests.